Reference at: http://www.consort.be/
D230

1.
Overview:
Modular system:
-
Built in a standard 19" rack and cabinet the central
unit accepts up to 7 modules. Different modules can be mixed in one unit.
-
There are two modules available: with four pH/mV/Ion/O2+
four emperature channels or with four conductivity/TDS + four tem-perature
channels.
-
All parameters including set-up, calibration and display
are control-led through any computer via a single RS232 connection.
-
Up to 16 units can be combined with each other to
increase the number of channels to a maximum of 448.
pH:
-
One- or two-point calibration.
-
Selectable resolution from 0.001 pH to 0.1 pH.
-
Automatic calibration with any of nine pre-programmed and
two user specified pH buffers.
mV:
-
Features mV calibration for accurate ORP measurements.
-
Selectable resolution from 0.1 mV to 1 mV.
Ion:
-
Direct concentration measurement.
-
Shows concentration in any unit.
-
Ion mode is easily calibrated with any two standards and
a blank correction.
Dissolved oxygen:
-
Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l
(1%).
-
Rapid air calibration, no zero calibration required.
-
Manual salinity compensation 0-40.
-
Manual air pressure compensation 800-1200 hPa.
Temperature:
-
Manual or automatic temperature compensation.
-
Calibrates temperature probe for quality measurements.
Conductivity:
-
One-point calibration.
-
Use a 1 cm-1electrode (standard) to measure
from 0.1 µS/cm to 200 mS/cm.
-
Use a 0.01 cm-1 electrode to measure from
0.001 µS/cm to 2 mS/cm.
-
Use a 0.1 cm-1 electrode to measure from 0.01
µS/cm to 20 mS/cm.
-
Use a 10 cm-1 electrode to measure from 1
µS/cm to 2000 mS/cm.
-
Selectable reference temperature: 20° or 25°C.
-
Automatic calibration with any of three preprogrammed and
three user specified standard solutions.
-
Accurate low conductivity measurements by eliminating the
capaci-tive component of the electrode and its cable (avoid the use of long
cables!).
Special features:
-
Three year warranty.
-
No electrical interference between electrodes in the same
solution.
Data acquisition:
-
The software package supplied with the D230 is specially
designed to
-
control, collect and store data. Runs under Windows™ 2000
or higher.
-
All channels are processed at the same time, each in its
own win-dow.
-
The software automatically detects the maximum number and
type of available channels.
-
Data is collected on-line at a programmable interval
determined by the program (4 s ... 24 h).
Table:
-
Data is always stored in a table.
-
Each module has its own programmable table containing an
un-limited number of lines (maximum depends on available computer
memory).
-
Comments can easily be added to each line in a special
information column.
Starting:
-
Data-logging can start/stop automatically or at a
programmable date/time.
-
Data-logging can be stopped or continued at any moment.
Files:
-
All data is saved in a user defined file. Just open the
file to view, process or print the stored data.
-
All measurements are saved in CSV format which is easily
trans-ferred into spreadsheets.
Graphs:
-
Graphs are generated using automatic or user defined
settings.
-
The number of visible values can be changed at any time.
-
Programmable alarm limits for each graph allow to print a
report indicating when limits have been exceeded.
-
Shows statistics about minima, maxima, averages etc...
Settings:
-
Languages: English, Dutch or French.
-
The style of each window can be set up separately.
-
Choose fonts, colours etc...
-
Documented printouts will show:
§ file name.
§ date and time.
§ name of the operator.
§ name of the company.
§ name of the division.
§ optional notes by the operator.
-
All settings are stored in a configuration file and
automatically recalled when opening the program.
Functions:
-
All functions are accessible through the menu.
-
Only valid options appear in the menu to eliminate set-up
errors.
-
Special buttons, icons and short-keys allow the user to
easily access the most useful functions.
-
The contents of each window can be transferred to other
programs by using a copy function.
-
Tile or cascade the windows and arrange the icons fully
automati-cally or rearrange them manually.
2.
Technical Data:
pH:
-
Range: 0...14 pH
-
Resolution: 0.001 pH
-
Accuracy: 0.1% ± 1 digit
-
Calibration: 1...2 points
-
Buffers: 9 pre-programmed; 2 user specified
-
Temperature compensation: -5...+105°C
-
ISO-pH: 6...8 pH
-
Slope: 80...120%
mV:
-
Range: ±2000 mV
-
Resolution: 0.1 mV
-
Accuracy: 0.1% ± 1 digit
-
Calibration: 1 point
ION:
-
Range: 0.01 ng/l...100 g/l
-
Resolution: 3 digits
-
Accuracy: 0.5% ± 1 digit
-
Calibration: 2 points + blank
DISSOLVED OXYGEN:
-
Range: 0...60 mg/l (0...600%)
-
Resolution: 0.01 mg/l (0.1%)
-
Accuracy: 1% ± 1 digit
-
Calibration: 1 point
-
Temperature compensation: 0...50°C
-
Salinity compensation: 0...40
-
Air pressure compensation: 800...1200 hPa
CONDUCTIVITY:
-
Range (cc dependent): 0...2000 mS/cm
-
Resolution (cc dependent): 0.001 µS/cm
-
Accuracy: 0.5% f.s. of range
-
Calibration: 1 point
-
Standards: 3 pre-programmed; 3 user specified
-
Cell constant (cc): 0.01/0.1/1/10 cm-1±30%
-
Temperature compensation: -5...+105°C
-
Reference temperature: 20° or 25°C
-
Temperature coefficient natural waters (EN27888)
-
Capacitive compensation
TDS:
-
Range: 0...100 g/l
-
Resolution: 0.01 mg/l
TEMPERATURE:
-
Range: -5...+105°C
-
Resolution: 0.1°C
-
Accuracy: 0.3°C
-
Calibration: 1 point
CHANNELS:
-
pH/mV/Ion/Dissolved oxygen: 4...28
-
Conductivity: 4...28
-
Temperature: 4...28
INPUTS:
-
pH/mV/Ion/Dissolved
oxygen: BNC, 1012Ω
-
Conductivity: BNC
-
Temperature: 2 banana, for Pt1000
CALIBRATION: GLP
DATA-LOGGING:
-
Data sets: unlimited
-
Interval: 4 s ... 24 h
SOFTWARE: Languages EN, NL, FR
SECURITY Password protection
AMBIENT CONDITIONS:
-
Temperature: 0...40°C
-
Humidity: 0...95%, non condensing
POWER SUPPLY: Mains 210...250 VAC, 50/60 Hz
DIMENSIONS: WxDxH 48x24x13 cm
WEIGHT: Meter 10 kg
3.
Order Info:
|
Item
|
Code
|
Description
|
|
01
|
D230
|
Data-logger: central unit for 7 modules + software +
RS232 cable
|
|
02
|
D291
|
Module for pH/mV/Ion/O2
/°C with 4+4 channels
|
|
03
|
D292
|
Module for conductivity/TDS/°C with 4+4 channels
|
|
04
|
D298
|
Data cable to connect 2 data-loggers with each other
(optional)
|
|
05
|
D299
|
Blanc frontpanel to cover unused module space
(optional)
|